TCDH F400 - TCDV F400

Roof fans F400 120

Centrifuges - Reaction < 25000 m3/h

TCDH F400 View larger

TCDH F400 - TCDV F400

Roof fans F400 120


Centrifuges - Reaction < 25000 m3/h

PIC-non-conforme.jpg Not ErP compliant
For smoke extraction only
or process ventilation
PIC-F400.jpg PIC-CE.jpg PIC-logiciel.jpg

  • F400 120 approved
  • Compatible with frequency variation
  • Reduced weight and dimensions
  • Economic range

Application

Smoke extraction in case of fire.
Extraction of stale air in process ventilation and data centers.


  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

11 sizes: 010 / 020 / 030 / 040 / 060 / 080 / 105 / 110 / 140 / 195 / 250.
Flows from 300 to 25,000 m3/h.
TCDH F400 with horizontal discharge:
  • Economy version.
  • Full engine protection.
TCDV F400 with vertical discharge:
  • Reduced sound level.
  • Engine and turbine fully concealed.
  • Less fouling of the immediate surroundings.
With INTZ or with INTZ + BDEZ (Switch + Depressostat).


Options - Corrosion treatment


Construction
  • Galvanized steel reaction turbine, mounted in direct coupling with the motor. Aluminum alloy hub. Suction plate, arm and motor support in galvanized sheet steel.
  • Cap in polyethylene gray color RAL 7040, with vertical jet TCDV F400, with horizontal jet TCDH F400 fixed by 4 nuts.
  • Anti-bird protection mesh.
  • Maximum exhaust air temperature in steady state: 40°C for TCDV F400 and 80°C for TCDH F400.

Motorization
  • Standard motor with B5 flange, class F, optional PTO thermal protection:
    • 1 speed single phase 230V, 50Hz, IP55.
      Accepts speed variation by voltage variator.
    • 1 speed three-phase 230/400V 50Hz 2-4-6-8 poles P
    • 1 three-phase speed 230/400V 50Hz 2-4-6-8 poles 0.75≤P≤7.5kW: IE3.
      Accepts speed variation by frequency variator.
    • 2 three-phase speeds, 400V, 50Hz, IP55.
  • INTZ: padlockable proximity switch with mounted/wired position feedback.
  • BDEZ: fitted pressure switch, not connected to the aeraulics, to be adjusted on site.

Selection of smoke extraction fans
TCDH F400

TCDV F400


Model

Ø Impeller (outer blades)

A

BV

CV

BH

CH

D

E

F

010

268

430

420

595

415

470

181

344

30

020

320

430

420

595

435

470

217

344

30

030

375

540

515

745

525

596

256

450

30

040

430

540

515

745

565

596

294

450

30

060

477

660

605

910

615

661

326

570

30

080

515

660

605

910

635

661

362

570

30

105

565

800

700

1100

760

849

399

668

30

110

630

800

700

1100

785

849

444

668

30

140

695

946

820

1280

913

1037

490

830

30

195

760

946

820

1280

938

1037

537

830

30

250

810

1030

920

1415

975

1037

581

830

40

Close Open Detailed specifications

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other

Close Open Fire / Smoke extraction certificates

Close Open Performance / Environment Certificates

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Close Open Commercial documents

Commercial leaflet (FCOM)

EASYVENT
Access the software online Media locked
ALL APPLICATIONS
LOGO_EASYVENT-WEB-bord-blanc.jpg Selection of fans and AHU
  • Creation of complete technical sheets with thermal data (CTA), fan operating points, acoustic characteristics and dimensional drawings.
Other products: permanent updates
BSP F400
CAB ECOWATT
CAD HR SLIM
CAD O INTEGRAL
CBM
CBM RE
CGT
CAT N F400
CHGT F400 - CHGT F300
CHRB/TN - CRVB/TN
CMB - CMT
CRHB-CRVB ECOWATT
CTB
CVAB N - CVAT N
CVAB N - CVAT N ECOWATT
FR F400
HCTB - HCTT - HCTT ATEX
HDB ATEX
HGHT F400 / F200
HGTT-V
HXBR - HXTR
HXBR ECOWATT
KABB - KABT
PURECLASS
TCBB - TCBT
TCTB ATEX - TGT ATEX
TCDH ATEX
TD - TD ECOWATT
TD ATEX
TD SILENT - TD SILENT ECOWATT
TGHT F400 - THGT F200
TGT
TGT ATEX
THC - THC ECOWATT
THGT HATCH F400
TRB - TREB
TXBR ECOWATT
ECOWATT WIND
VENT-NK - VENT-VN


OPTAIR Ventilation
Download OPTAIR Ventilation Media locked
VMC SMOKE EXHAUST
OPTAIR-Ventilation.png Selection of turrets and boxes: KDT / KSH / TCD / KUBAIR / TED
  • VScreation of a technical sheet per fan including the requested operating point on the curve, the technical and acoustic characteristics, and the overall dimensions
  • Printing possibility
  • Link to all technical pages Catalog
KCTR F400
KDTA BP
KDTA F400
KDTR BP
KDTR F400
KSHA
KSHP
KSHR
KUBAIR F400 CC
KUBAIR F400 ECOWATT CC
KUBAIR F400 ECOWATT MV
KUBAIR F400 MV
TCDH F400
TCDV F400
TEDH F400
TEDH F400 ECOWATT
TEDV F400
TEDV F400 ECOWATT

Close Open BUFFALO GRILL - ANNEMASSE

Restaurant chains

74 - Haute-Savoie

Close Open BUFFALO GRILL - ECOUFFANT

Restaurant chains

49 - Maine-et-Loire

Close Open BUFFALO GRILL - MARLENHEIM

Restaurant chains

67 - Bas-Rhin

Close Open BUFFALO GRILL - SAINT PAUL LES DAX

Restaurant chains

40 - Landes

Close Open CENTRE DE DETENTION (600 PLACES) - ROANNE

Prisons

42 - Loire

Close Open CENTRE HOSPITALIER - PLERIN

Hospitals

22 - Côtes-d'Armor

Close Open CENTRE HOSPITALIER INTERCOMMUNAL - ANNEMASSE-BONNEVILLE

Hospitals

74 - Haute-Savoie

Close Open CENTRE PENITENTIAIRE (690 PLACES) - NANCY-MAXEVILLE

Prisons

54 - Meurthe-et-Moselle

Close Open CENTRE PENITENTIAIRE (810 PLACES) - BEZIERS

Prisons

34 - Herault

COMPLEXE PIERRES VIVES - MONTPELLIER

Close Open COMPLEXE PIERRES VIVES - MONTPELLIER

Media library

34 - Herault

DEMEURE DE PRESTIGE LA COQUILLADE - GARGAS

Close Open DEMEURE DE PRESTIGE LA COQUILLADE - GARGAS

Independent commercial catering

84 - Vaucluse

EHPAD TAMARIS - AYTRE

Close Open EHPAD TAMARIS - AYTRE

Residences for the elderly

17 - Charente-Maritime


Installed products:


Close Open IME KERVIHAN - BREHAN

Healthcare establishments

56 - Morbihan

LES HALLES SOLANID - LODEVE

Close Open LES HALLES SOLANID - LODEVE

Community restaurants / RIE

34 - Herault

Close Open MAISON D’ARRET (690 PLACES)- LYON-CORBAS

Prisons

69 - Rhône

X