JBRB ECOWATT® PR VCHV

Regulated C4 extraction boxes

Direct drive - Reaction - ECM

Flag Nouveau
JBRB ECOWATT® PR VCHV View larger

JBRB ECOWATT® PR VCHV

Regulated C4 extraction boxes


Direct drive - Reaction - ECM

PIC-ERP-conforme-01.jpg ErP compliant 2018
UVNR - Variable EC motor
PIC-Isolation-acoustique-01.jpg PIC-ATEC-HYGRO-CSTB-01.jpg ECM motor
Acoustic insulation Easy maintenance OPTAIR RT Conso

  • Low power ECM motor out of the air stream
  • High performance reaction wheel
  • Constant pressure operation COP
  • Conformity with Hygro technical notice
  • Multiple installation configurations
  • Easy maintenance
  • Single or three-phase

Application
Air extraction.
Indoor or outdoor installation.
Approved 400°C 1/2h category C4.
CMV in collective housing and tertiary premises.
Air return in tertiary premises.
  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow rates from 100 to 9200 m3/ h.
10 sizes: 04/06/10/22/30/38/48/70/82/92.
Available configurations:
  • L: online.
  • M: modular, supplied with a cap for 1 or 2 90 ° aspirations.
  • D: double suction at 180 °.
Horizontal or vertical discharge version.
Insulated version: acoustic insulation by 25 mm glass wool (M0 fire classification) in double skin panels.


Options - CORROSION PROTECTION


Construction
  • Galvanized sheet steel casing equipped with 4 fixing brackets (size 04 to 38) or 2 transerval omegas (sizes 48 to 92).
  • Lifting by 2 steel legs or by slinging through the omegas.
  • Connection nozzle with class D sealing gaskets. Vertical discharge version supplied without connection nozzle (flat nozzle with PAPV seal to be fitted as an option with self-drilling screws).
  • Direct coupling.
  • INTZ: mounted / wired padlockable proximity switch.
  • BDEZ: Depressostat fitted, air-connected, factory set at 80 Pa.
  • High performance galvanized steel reaction turbine.
  • Lid equipped with 2 or 4 handles, removable without tools to ensure easy access to the interior of the box for cleaning.
  • Horizontal or vertical discharge version.
  • IS version: Acoustic insulation by 25 mm A2-s1, d0 (M0) glass wool in double skin panels.
  • Corrosion resistance treatment option: contact us.
Motorization
  • ECM electronically commutated motor out of air flow:
    • 04 to 22: IP44 class B single phase 230V, 50Hz.
    • 30, 38, 48, 70, 82: IP54, class F, single phase 230V, 50Hz.
    • 30, 38, 48, 70, 92: IP 54, class F, three-phase 400V, 50Hz.
  • Thermal protection managed by electronics and approved for C4 operation.
VCHV regulation
  • Operation in COP (constant pressure).
  • Control box, IP54, factory fitted and wired.
  • 4-digit display with setpoint adjustment keys
    • Clear display of the pressure measurement and the set point.
JBRB ECOWATT® PR VCHV 04/06/10/22/30/38 - L / M
Horizontal discharge




--- Available only on the modular version "M"

Model A B B1 C* D1 E F G H I J Weight (kg)
JBRB ECOWATT® PR VCHV 04 627 523 533 320 160 568 502 157 175 157 161 22
JBRB ECOWATT® PR VCHV 06 627 523 533 320 200 568 502 157 175 157 161 22
JBRB ECOWATT® PR VCHV 10 627 566 583 421 250 569 544 207 185 207 186 26
JBRB ECOWATT® PR VCHV 22 767 683 701 511 355 709 661 252 237 252 239 45
JBRB ECOWATT® PR VCHV 30 1019 820 873 568 400 892 797 267 271 267 271 64
JBRB ECOWATT® PR VCHV 38 1153 938 971 631 500 1036 907 306 331 306 331 78

* IS version: +27 mm


JBRB ECOWATT® PR VCHV 48/70/82/92 - L / M
Horizontal discharge



--- Available only on the modular version "M"


Model A B B1 C* D1 E F G H I J Weight (kg)
JBRB ECOWATT® PR VCHV 48 1165 985 1065 800 560 700 918 433 330 433 330 107
JBRB ECOWATT® PR VCHV 70 1280 1030 1100 880 630 815 970 473 365 473 365 121
JBRB ECOWATT® PR VCHV 82 1404 1100 1175 970 710 846 1032 518 405 518 405 170
JBRB ECOWATT® PR VCHV 92 1404 1100 1175 970 710 846 1032 518 405 518 405 170

* IS version: +27 mm


JBRB ECOWATT® PR VCHV 04/06/10/22/30/38 - L / M
Vertical discharge



--- Available only on the modular version "M"

Model A B B1 C* D1 E F G H I J Weight (kg)
JBRB ECOWATT® PR VCHV 04 648 523 533 320 160 568 502 157 175 130 165 22
JBRB ECOWATT® PR VCHV 06 648 523 533 320 200 568 502 157 175 130 165 22
JBRB ECOWATT® PR VCHV 10 648 566 583 421 250 569 544 207 185 166 198 26
JBRB ECOWATT® PR VCHV 22 789 683 701 511 355 709 661 252 237 236 271 45
JBRB ECOWATT® PR VCHV 30 1019 820 873 565 400 892 797 267 271 248 286 64
JBRB ECOWATT® PR VCHV 38 1153 938 971 637 500 1036 907 306 331 315 350 78

* IS version: +27 mm



JBRB ECOWATT® PR VCHV 48/70/82/92 - L / M
Vertical discharge




--- Available only on the modular version "M"

Model A B B1 C* D1 E F G H I J Weight (kg)
JBRB ECOWATT® PR VCHV 48 1119 985 1065 800 560 700 918 433 330 320 340 107
JBRB ECOWATT® PR VCHV 70 1234 1030 1100 880 630 815 970 473 365 370 375 121
JBRB ECOWATT® PR VCHV 82 1358 1100 1175 970 710 846 1032 518 405 482 415 170
JBRB ECOWATT® PR VCHV 92 1358 1100 1175 970 710 846 1032 518 405 482 415 170

* IS version: +27 mm


JBRB ECOWATT® PR VCHV 10/22/30/38 - D
Horizontal discharge




Model A B C* D1 D2 E F G H I J Weight (kg)
JBRB ECOWATT® PR VCHV 10 815 603 421 250 200 777 544 194 161 207 186 28
JBRB ECOWATT® PR VCHV 22 1048 720 511 355 315 998 661 239 219 252 239 45
JBRB ECOWATT® PR VCHV 30 1324 930 566 400 355 1238 797 267 247 267 271 67
JBRB ECOWATT® PR VCHV 38 1468 1024 631 500 400 1396 908 306 281 306 331 83

* IS version: +27 mm



JBRB ECOWATT® PR VCHV 48/70/82/92 - D
Horizontal discharge



Model A B C* D1 D2 E F G H I J Weight (kg)
JBRB ECOWATT PR VCHV 48 1490 1105 800 560 450 990 918 433 270 433 330 135
JBRB ECOWATT PR VCHV 70 1691 1183 880 630 500 986 978 473 301 473 365 150
JBRB ECOWATT PR VCHV 82 1813 1237 970 710 560 1016 1032 518 340 518 405 200
JBRB ECOWATT PR VCHV 92 1813 1237 970 710 560 1016 1032 518 340 518 405 200

* IS version: +27 mm



JBRB ECOWATT® PR VCHV 10/22/30/38 - D
Vertical discharge



Model A B C* D1 ** D2 E F G H Weight (kg)
JBRB ECOWATT PR VCHV 10 804 603 421 250 200 777 544 194 161 28
JBRB ECOWATT PR VCHV 22 1037 720 511 355 315 998 661 239 219 45
JBRB ECOWATT PR VCHV 30 1276 930 566 400 355 1238 797 267 247 67
JBRB ECOWATT PR VCHV 38 1426 1025 637 500 400 1396 909 306 281 83

* IS version: +27 mm - ** If adding a PAPV flat nozzle to connect the discharge



JBRB ECOWATT® PR VCHV 48/70/82/92 - D
Vertical discharge



Model A B C* D1 ** D2 E F G H Weight (kg)
JBRB ECOWATT PR VCHV 48 1444 1105 800 560 450 990 918 433 270 135
JBRB ECOWATT PR VCHV 70 1697 1183 880 630 500 986 978 473 301 150
JBRB ECOWATT PR VCHV 82 1767 1237 970 710 560 1016 1032 518 340 200
JBRB ECOWATT PR VCHV 92 1767 1237 970 710 560 1016 1032 518 340 200

* IS version: +27 mm - ** If adding a PAPV flat nozzle to connect the discharge

Close Open Detailed specifications

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other

Installation instructions (NT) Other languages

Close Open Performance / Environment Certificates

Close Open Prescription assistance

Specification text (TP)

X