JBHB ECOWATT PR

Regulated C4 extraction boxes

Direct drive - Forward - ECM < 2700 m3/h

JBHB ECO ECM PR View larger

JBHB ECOWATT PR

Regulated C4 extraction boxes


Direct drive - Forward - ECM < 2700 m3/h

PIC-ERP-conforme-01.jpg ErP 2018 Compliant - UVNR - Variable EC Motor
PIC-COP.jpg PIC-C4-confort-01.jpg PIC-ATEC-HYGRO-CSTB-01.jpg PIC-Moteur-ecm-01.jpg PIC-LOGICIEL-01.jpg

  • Low consumption ECM motor
  • Constant pressure operation COP
  • Low noise level
  • Compliance with Hygro Technical Notice and CPT 3827 - Cdep 2

Application

Air extraction.
Indoor or outdoor installation.
Approved 400°C 1/2h category C4.
VMC in collective housing and tertiary premises.
Air intake in tertiary premises.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Flow rates from 50 to 2,700 m3/h.
5 sizes: 07 / 12 / 15 / 21 / 27.
With INTZ.

JBHB ECO ECM PR - Main spare parts


Construction
  • Box made of galvanized Z275 steel sheet.
  • Connection tappings with class D sealing gaskets.
  • Single action inlet fan.
  • Direct coupling.
  • IP55 control box.
  • Discharge grid allowing access to the wheel for cleaning.
  • Baffle with acoustic foam as standard in configuration D.
  • INTZ : padlockable proximity switch with mounted/wired position feedback.

Motorization
  • Electronically commutated motor ECM, excluding airflow:
    • IP44 class B mono, 230V 50Hz.
    • IP44 class F single phase, 230V 50Hz, size 21.
  • Electronically controlled thermal protection.

RMED regulation
  • Operation in COP (constant pressure)
  • Control box, IP55, factory mounted and wired.
  • Backlit LCD display, with function keys on the front.
  • Clear display of the measurement (pressure) and the set value.
  • Integrated ventilation fault signaling: dry contact available on the RMED terminal block.
  • Serial ModBus communication.

C4 fan selection - 400°C 1/2H
JBHB ECOWATT PR

90° elbow (C)
JBHB-ECOWATT-PR-C-dim.jpg
Double side suction (D)
JBHB-ECOWATT-PR-D-dim.jpg

Model

Config.

Dimensions

A

B

C

Ø D1

Ø D2

E

JBHB ECO WATT PR 07

C

487

420

325

250

170

D

707

420

325

250

200

175

JBHB ECO WATT PR 12

C

482

445

380

250

192

D

702

445

380

250

200

212

JBHB ECO WATT PR 15

C

532

500

410

315

227

D

782

500

410

315

250

212

JBHB ECO WATT PR 21

C

532

500

410

315

227

D

782

500

410

315

250

212

JBHB ECO WATT PR 27

C

595

595

500

400

250

D

920

595

500

400

355

250


Model

Config.

Dimensions

F

G

H

I

K

L

M

JBHB ECO WATT PR 07

C

45

137

50

425

400

D

148

45

43

367

47

645

400

JBHB ECO WATT PR 12

C

45

139

61

420

425

D

153

45

35

361

61

640

425

JBHB ECO WATT PR 15

C

45

168

57

470

480

D

171

45

43

421

57

720

480

JBHB ECO WATT PR 21

C

45

168

57

400

480

D

171

45

43

421

57

720

480

JBHB ECO WATT PR 27

C

50

217

55

530

575

D

228

50

43

545

53

860

575

Close Open Detailed specifications

Text catalog pages (CT)

Catalog Pages - Other

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Close Open Performance / Environment Certificates

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

OPTAIR RT Conso
Download OPTAIR Conso Media locked
COLLECTIVE AND TERTIARY VMC
OPTAIR-RT-Conso.png Calculation of VMC flow rates

Selection of VMC boxes
  • Automatic calculation of min/max flow rates DTU 68.3 and RT2012
  • Selection of suitable fans
  • Detailed technical sheet with fan consumption determined according to its operating point, following Th-BCE rules
  • Automatic app update (requires internet connection)
ALIZE AUTO
ALIZE HYGRO
JBEB MV
JBHB ECO ECM PR
JBRB ECOWATT
JBRB ECOWATT PR
JBRB ECOWATT PM
JBRE AC (bientôt disponible)
JBRE ECOWATT
JBRE ECOWATT PR
KMDT - KMDT PM
KSTD
KSTD ECOWATT
KSTD IP
KUBAIR F400 ECOWATT MV
TCRH TCRV ECOWATT
TCRH TCRV ECOWATT PR
TCSH
TCSH ECOWATT
TECH C4 ECOWATT (bientôt disponible)
TEDH TEDV C4 ECOWATT
TEDH TEDV C4 ECOWATT PR
TEDH TEDV F400 ECOWATT
THERMOGAZ

OPTAIR VMC
Download OPTAIR VMC Media locked
COLLECTIVE AND TERTIARY VMC
OPTAIR-VMC.png Sizing of VMC installations

Material list and quote
  • Network sizing and selection of the appropriate fan.
  • Works for any self-adjusting, hygro-adjustable and gas installation.
  • Calculations in accordance with current standards.
  • Provides a detailed and costed list of selected hardware.
  • Allows quotes to be produced from the VIM product database.
  • Possible application in TERTIARY single-flow VMC.
ALIZE AUTO
ALIZE HYGRO
JBEB MV
JBHB ECO ECM PR
JBRB ECOWATT
JBRB ECOWATT PR
JBRB ECOWATT PM
JBRE AC (bientôt disponible)
JBRE ECOWATT
JBRE ECOWATT PR
KMDT - KMDT PM
KSTD
KSTD ECOWATT
KSTD IP
KUBAIR F400 ECOWATT MV
TCRH TCRV ECOWATT
TCRH TCRV ECOWATT PR
TCSH
TCSH ECOWATT
TECH C4 ECOWATT (coming soon)
TEDH TEDV C4 ECOWATT
TEDH TEDV C4 ECOWATT PR
TEDH TEDV F400 ECOWATT
THERMOGAZ