CAD HR GLOBAL LP FW

Old ranges

Counter flow - Ceiling unit - ECM < 2 000 m3/H

FLAG Obsolete
CAD HR GLOBAL LP View larger

CAD HR GLOBAL LP FW

Old ranges


Counter flow - Ceiling unit - ECM < 2 000 m3/H

erp.jpg ErP 2018 compliant - UVNR
Variable EC motors
Filters size 450
Supplied as standard: Blowing fresh air G4 (coarse 65%). Reprise stale air G4 (coarse 65%).
Optional : Possibility of replacing the G4 filter (coarse 65%) by an F7 filter (ePM1 60%) at blowing of fresh air with a G4 / F7 kit or to replace the G4 filters (coarse 65%) by M5 filters (ePM10 50%) to the reprise of stale air and F7 (ePM1 60%) on fresh air.

Filters other sizes
Supplied as standard: Blowing fresh air M5 (ePM10 50%). Reprise stale air M5 (ePM10 50%).
Optional : Possibility of replacing the M5 filter (ePM10 50%) by an F7 filter (ePM1 60%) at blowing fresh air (Kit M5 / F7).
echangeur.jpg ecm.jpg bypass.jpg pression.jpg
modbus.jpg plug-and-play.jpg logiciel.jpg
Logo-EUROVENT.jpg
Air-to-air plate heat exchangers produced by the company KLINGENBURG, which participates in the Eurovent program. Certification for AAHE.




  • Extra-flat: maximum height 400 mm
  • Double skin rock wool insulation 30 mm
  • External battery
  • Low consumption ECM motor
  • By-pass 100% proportional pilot
  • TAC5 regulation ready to connect
  • Thermal efficiency up to 92%

Application

Air introduction and extraction with energy recovery in tertiary premises.
Particularly suitable for installation in false ceilings in renovation as in new.
Indoor use only.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

  • 5 sizes: 450/600/1000/1600/2000 m3/ h.
  • 2 models:
    • R: blowing on the right of the control box,
    • L: blowing on the left.
  • Online duct connection configuration.
  • Communicating TAC5 regulation:
    • Modbus RTU- RS485,
    • Modbus TCP / IP,
    • KNX TP,
    • Wifi: smartphone application, tablet,
    • Ethernet: PC application,
    • BACnet gateway.

Construction
  • Box with self-supporting structure in galvanized steel.
  • Double skin panels 30 mm thick with rock wool insulation (Euroclass A1), thermal conductivity 0.035W / (mk).
  • Polyester-type prepainted steel exterior finish (5µm primer +
    20 µm polyester).
    • Interior finish in galvanized steel (5μm primary + 20μm polyester).
  • Classification EN 1886 D1 / L3 / F8 / T3 / TB2.
  • Airtightness according to standard EN 13141-7:
    • internal leakage: class 1; external leak: class 2.
  • Access to filters and exchanger from below.
  • Drip tray equipped with a condensate drain pump (factory connected) and drain pipe (Ø 10 mm).
  • By-pass 100%, controlled by a proportional servomotor, used for free cooling and the antifreeze strategy of the exchanger.
  • Supplied with 4 mounted / wired probes.

Motorization

  • Galvanized steel double inlet fan.
  • Low consumption, direct current, 230 V single-phase ECM motor. Electronic thermal protection - manual reset.

Exchanger

  • High efficiency air / air countercurrent heat exchanger made of “seawater resistant” aluminum for an operating temperature of up to 80 ° C. Thermal efficiency up to 92%.

Filters size 450
  • On delivery G4 filters (coarse 65%) during extraction. G4 (coarse 65%) to the fresh air intake. Possibility, as an accessory, to replace the G4 filter (coarse 65%) by an F7 filter (ePM1 60%) air intake by
    1 Kit G4 / F7 or replace G4 filters (coarse 65%) by M5 filters (ePM10 50%) at extraction and F7 (ePM1 60%) on fresh air.

Filters other sizes
  • On delivery, M5 filters (ePM10 50%) extraction and M5 (ePM10 50%) New air. Possibility of replacing the M5 filter (ePM10 50%) by an F7 filter (ePM1 60%) to the fresh air intake (Kit M5 / F7) as an accessory.
  • Filters are easily accessible from underneath the unit.

TAC control ready to plug in
  • Complete regulation allowing 3 operating modes:
SETTING THE FLOW RATES RECOMMENDED APPLICATIONS
LS MODE - VARIABLE FLOW RATE
Fan speed variation by 0-10 V signal
- Flow rate setpoint according to a 0-10 V signal from an external sensor (CO2, temperature, humidity, etc.) - Single-zone installation, requiring adaptation of ventilation according to occupancy
AC MODE - CONSTANT FLOW
Fan speeds defined according to a precise flow rate
- 3 maximum constant flow setpoints, input of values with reading on display.
- Switching between the different setpoints carried out manually from the remote control or automatically by clock or presence detection.
- Installations requiring the control of one or more precise flow rates.
CPs MODE - CONSTANT PRESSURE
Automatic variation of fan speed to maintain constant pressure
Flow automatically modulated in order to maintain a constant pressure value measured by an external probe (pressure probe as an accessory). Multi-zone ventilation systems, associated with modulation of terminal airflows.

  • The operation of the exhaust fan is slaved to the supply fan. Its flow rate corresponds to a percentage of the flow rate of the supply fan (generally 100%).
  • Programmable and controllable regulation from the remote control.

Regulation accessories
  • HMI TACtouch 4.3 "touchscreen, IP20 for parameter setting, control, visualization.
  • SAT3, circuit with 2 relays for:
    • Pressure alarm signaling and "fan on" signal and / or circulator control and bypass status.
  • SAT MODBUS, allows the options below:
    • Connection to a GRC (remote control with touch screen),
    • Communication in Modbus RTU - Control and visualization via a BMS.
  • SAT ETHERNET:
    • Communication with Modbus TCP / IP protocol in Ethernet network on 10 BASE T twisted pair. Allows communication with a BMS or interfacing with the EOLE4HR application for smartphone, tablet and PC (Android, IOS or Windows 7/8/10) .
  • SAT BA / KW kit allows the control of the external batteries from the TAC5 regulation.
  • SAT WIFI:
    • Communication with Modbus TCP / IP protocol by WIFI. Allows communication with a BMS or interfacing with the EOLE4HR application for smartphone, tablet and PC (Android, IOS or Windows 7/8/10).

Product Accessories:
KWIN - Integrated antifreeze electric heater
  • Supplied fully pre-wired with regulation.
  • Accepts a temperature of -20 ° C at the intake for an internal temperature of 20 ° C, without risk of the exchanger freezing.
  • Includes: static relay for modulating the heating power, temperature probe, thermal protection with automatic reset (75 ° C) and manual reset (100 ° C).

CBAE - box for external hot water or chilled water coil

  • Box with aluminum profile structure and 30 mm thick double skin panel, with thermal insulation made from rock wool (Euroclass A1), thermal conductivity 0.035W / (mk)

Batteries for CBAE:

  • BAEC: hot water coil 2 or 4 rows,
  • BAEF: 4-row cold water coil equipped with a condensate collection tray and an evacuation pump. The batteries can be optionally fitted with a V3V / servomotor / SAT BA / KW kit comprising:
    • the SAT BA / KW kit for connection to the TAC5 regulation with 2 temperature probes, one of which is a contact for the coil's antifreeze protection + 1 motorized 3V valve.
  • BADX: direct expansion coil
    • 4-row coil, for R410 fluid, equipped with a condensate pan and an evacuation pump.
    • Battery delivered without regulation

Air treatment selection
Outdoor air
Extract air
Supply air
Exhaust air

CAD HR GLOBAL LP 450 FW L
Weight 87 kg
CADHR-GLOBAL-LP-450-L-dim.png

CAD HR GLOBAL LP 450 FW R
Weight 87 kg
CADHR-GLOBAL-LP-450-R-dim.png

CAD HR GLOBAL LP 600 FW L
Weight 119 kg
CADHR-GLOBAL-LP-600-L-dim.png

CAD HR GLOBAL LP 600 FW R
Weight 119 kg
CADHR-GLOBAL-LP-600-R-dim.png

CAD HR GLOBAL LP 1000 FW L
Weight 165 kg
CADHR-GLOBAL-LP-1000-L-dim.png

CAD HR GLOBAL LP 1000 FW R
Weight 165 kg
CADHR-GLOBAL-LP-1000-R-dim.png

CAD HR GLOBAL LP 1600 FW L
Weight 215 kg
CADHR-GLOBAL-LP-1600-L-dim.png

CAD HR GLOBAL LP 1600 FW R
Weight 215 kg
CADHR-GLOBAL-LP-1600-R-dim.png


CAD HR GLOBAL LP 2000 FW L
Weight 261 kg
CADHR-GLOBAL-LP-2000-L-dim.png

CAD HR GLOBAL LP 2000 FW R
Weight 261 kg



X