CAD HR MURAL UP 450

Old ranges

Counter flow - Action - ECM

FLAG Obsolete
CAD HR MURAL UP 450 View larger

CAD HR MURAL UP 450

Old ranges


Counter flow - Action - ECM

PIC-ERP-2018.jpg PIC-Coffret-monte-cable.jpg recuperation-nrj
  • Double skin 15 mm
  • External battery
  • Low consumption ECM motor
  • TAC5 regulation ready to connect
  • Thermal efficiency up to 92%

Application

Air introduction and extraction with energy recovery in tertiary premises.
Indoor installation.
Vertical construction, connection on top.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

1 size.
TAC5 DM regulation with integrated display and programming keys.
Communication possible Modbus RTU RS485, Modbus TCP / IP KNX type TP, application for smartphone, tablet or PC (Android, IOS, Windows 7/8/10).

Construction
  • Box with self-supporting structure.
  • Double skin panel 15 mm thick with rock wool insulation (Euroclass A1) thermal conductivity 0.035W / (mk).
  • External finish in prepainted steel of silicone heat-crosslinkable polyester type (5 μm primary + 20 μm polyester).
  • Interior finish in galvanized steel.
  • Access to the filters and the exchanger from the main face using a removable panel.
  • Condensate collection tray with Ø 20 mm drain.
  • Single inlet action fan.
  • By-pass 50%.
  • Supplied with 3 probes mounted / wired for automatic management of the bypass and antifreeze protection.
Motorization
  • Low consumption, direct current, 230 V single-phase ECM motor. Electronic thermal protection - manual reset.
Exchanger
  • High efficiency air / air countercurrent heat exchanger made of aluminum for an operating temperature of up to 80 ° C. Thermal efficiency up to 92%.
Filters
  • G4 filters for air extraction and introduction. Easily accessible from the main side.
TAC5 DM control unit ready to connect
  • Complete regulation allowing 3 operating modes:
    • LS MODE - VARIABLE FLOW RATE
    • AC MODE - CONSTANT FLOW
    • CPs MODE - CONSTANT PRESSURE
  • The operation of the exhaust fan is slaved to the supply fan. Its flow rate corresponds to a percentage of the flow rate of the supply fan (generally 100%).
Regulation accessories
  • RC TAC5 remote control
  • Direct connection to the regulation.
  • Entry of all operating parameters.
  • Fan speed control.
  • Visualization of all parameters and alarms.
  • Connection to be made by the installer (maximum length 1000 m).
  • IP20 remote control.
SAT3
  • Signals the actual operation of the fan via a potential-free contact (relay normally open) (relay R3)
  • Ex: authorization of operation of an external battery (post-ventilation function that can be programmed).
  • Signals the alarm on a pressure variation (relay R2).
SAT TAC5 BA / KW
  • Modulates the power of the batteries in order to maintain the supply temperature equal to the setpoint.
  • Provides antifreeze protection for water coils.
  • Gives a control contact for the circulator.
  • Manages the hot / cold passage via a digital input.
  • Allows the batteries to be switched off via a digital input.
CAD HR Mural UP 450

Indoor version - Vertical installation - Connection from above


Close Open Detailed specifications

Text catalog pages (CT)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other