Search a product :
New product
Not ErP compliant For process ventilation |
Filters
|
||||
Introduction of fresh air, heating, air conditioning in process ventilation.
Installation inside or outside of buildings.
Treated air temperature: -20 ° C to + 40 ° C.
ErP compliant for unit heater application 100% recycling.
Description
Dimensions
Documentation
Public Price
Software
References
Model |
Box dimensions |
Suction dimensions |
Fixings |
Dimensions |
||||||||
A |
B |
C |
E |
F |
G |
H |
J |
P |
Q |
RH |
RV |
|
KSTA 7 - 2 rows / KSTV 7 |
1088 |
630 |
474 |
375 |
500 |
71 |
823 |
650 |
240 |
250 |
172 |
137 |
KSTA 7 - 4 rows / KSTV 7 |
||||||||||||
KSTA 9 - 2 rows / KSTV 9 |
1187 |
730 |
568 |
475 |
600 |
65 |
922 |
750 |
278 |
318 |
193 |
165 |
KSTA 9 - 4 rows / KSTV 9 |
||||||||||||
KSTA 10 - 2 rows / KSTV 10 |
1236 |
830 |
654 |
550 |
700 |
76 |
971 |
850 |
307 |
351 |
213 |
185 |
KSTA 10 - 4 rows / KSTV 10 |
||||||||||||
KSTA 12 - 3 rows / KSTV 12 |
1365 |
930 |
790 |
675 |
800 |
87 |
1100 |
950 |
359 |
414 |
244 |
216 |
KSTA 12 - 4 rows / KSTV 12 |
||||||||||||
KSTA 15 - 3 rows / KSTV 15 |
1562 |
1045 |
900 |
775 |
900 |
97 |
1247 |
1065 |
421 |
491 |
271 |
243 |
KSTA 15 - 4 rows / KSTV 15 |
||||||||||||
KSTA 18 - 3 rows / KSTV 18 |
1886 |
1245 |
1030 |
875 |
1100 |
127 |
1571 |
1265 |
497 |
574 |
325 |
297 |
KSTA 18 - 4 rows / KSTV 18 |
Model |
Dimensions |
Weight |
Water coil weight (kg) |
|||||||
S |
T |
U |
V |
W |
X * |
ØD |
Simple |
Isolated |
||
KSTA 7 - 2 rows / KSTV 7 |
270 |
78 |
292 |
92 |
745 |
1 " |
35 |
50 |
9 |
|
KSTA 7 - 4 rows / KSTV 7 |
265 |
90 |
286 |
94.5 |
745 |
349 |
1 " |
10 |
||
KSTA 9 - 2 rows / KSTV 9 |
360 |
40 |
302 |
94 |
845 |
1 " |
55 |
80 |
9 |
|
KSTA 9 - 4 rows / KSTV 9 |
360 |
78 |
283 |
94 |
845 |
349 |
1 " |
14 |
||
KSTA 10 - 2 rows / KSTV 10 |
450 |
78 |
292 |
92 |
945 |
1 " |
70 |
100 |
16 |
|
KSTA 10 - 4 rows / KSTV 10 |
445 |
90 |
286 |
94.5 |
945 |
349 |
1 " |
18 |
||
KSTA 12 - 3 rows / KSTV 12 |
565 |
60 |
292 |
102.5 |
1045 |
1 " |
80 |
115 |
18 |
|
KSTA 12 - 4 rows / KSTV 12 |
570 |
78 |
283 |
100 |
1045 |
349 |
1 " |
23 |
||
KSTA 15 - 3 rows / KSTV 15 |
685 |
60 |
342 |
97.5 |
1145 |
1 " |
110 |
155 |
23 |
|
KSTA 15 - 4 rows / KSTV 15 |
677 |
78 |
333 |
101.5 |
1160 |
399 |
1 1/2 " |
31 |
||
KSTA 18 - 3 rows / KSTV 18 |
798 |
60 |
342 |
106 |
1355 |
1 1/4 " |
190 |
265 |
32 |
|
KSTA 18 - 4 rows / KSTV 18 |
791 |
78 |
333 |
109.5 |
1360 |
399 |
2 " |
41 |
* Reversible battery only,
** Without engine, filter or water battery.
Detailed specifications
Text catalog pages (CT)
Installation instructions
Installation instructions (NT)
Installation instructions (NT) Other
Detailed specifications
Text catalog pages (CT)
Installation instructions
Installation instructions (NT)
Installation instructions (NT) Other
Manufacturing premises
73 - Savoy
Installed products:
Restaurant chains
16 - Charente
Installed products:
Specialized education
69 - Rhône
Année : 2016
Maître d'ouvrage : OL ASSOCIATION LYON
BET Fluides : GC2E
Installateur : MEDT (dep. 38)
Architecte : ROCHE THIERRY ASSOCIÉS
Installed products:
Colleges
21 - Côte-d'Or
Installed products:
Central kitchen / Food industry
33 - Gironde
Année : 2014
Maître d'ouvrage : VILLE DE PESSAC
BET Fluides : CETAB
Installateur : HERVE THERMIQUE (dep. 33)
Architecte : FERRON ET MONNEREAU
Installed products:
Central kitchen / Food industry
01 - Ain
Année : 2012
Installateur : JOSEPH (dep. 01)
Installed products:
Community restaurants / RIE
69 - Rhône
Année : 2015
Maître d'ouvrage : HÔPITAL DE BELLEVILLE
BET Fluides : SYNAPSE
Installateur : GUERIN (dep. 71)
Installed products:
Community restaurants / RIE
21 - Côte-d'Or
Année : 2015
Maître d'ouvrage : DV ORANGE
Installateur : SPIE EST (dep. 21)
Installed products:
Community restaurants / RIE
71 - Saône-et-Loire
Année : 2015
Maître d'ouvrage : ASSOCIATION DES PAPILLONS BLANCS
BET Fluides : DAVENTURE
Installateur : QUESADA (dep. 71)
Architecte : REGNAULT ACHITECTE
Installed products:
Independent commercial catering
84 - Vaucluse
Installed products:
Residences for the elderly
24 - Dordogne
Année : 2015
Installateur : SALLERON (dep. 24)
Installed products:
Residences for the elderly
88 - Vosges
Année : 2014
Maître d'ouvrage : CCAS REMIREMONT
BET Fluides : IOSIS
Installateur : IMHOFF (dep. 88)
Architecte : JANIAUD ALAIN
Installed products:
Residences for the elderly
29 - Finistère
Année : 2016
Maître d'ouvrage : MFBREST29
BET Fluides : BE ADRET
Installateur : ELORN PLOMBERIE CHAUFFAGE (dep. 29)
Architecte : COLLECTIF D'ARCHITECTES FAUVET - SAGAZAN - LE STER
Installed products:
Colleges
74 - Haute-Savoie
Installed products:
Funeral home
71 - Saône-et-Loire
Année : 2014
Installateur : ARNOUD ET ASSOCIES (dep. 71)
Architecte : AMD ARCHITECTES
Installed products:
Hotels
64 - Pyrénées-Atlantiques
Installed products:
Shopping centers
68 - Haut-Rhin
Année : 2015
Maître d'ouvrage : IKEA DEVELOPPEMENT
BET Fluides : OTE
Installateur : EIMI (dep. 25)
Architecte : AEA ARCHITECTES
Installed products:
Specialized education
30 - Gard
Année : 2015
Maître d'ouvrage : CHAMBRE DES MÉTIERS DU GARD
BET Fluides : CETEX INGENIERIE
Installateur : JULLIAN ET CIE (dep. 30)
Architecte : PIRO ET BERARDI
Installed products:
Independent commercial catering
44 - Loire-Atlantique
Installed products:
Independent commercial catering
73 - Savoy
Installed products:
Shopping centers
2A - Corse-Du-Sud
Année : 2017
Maître d'ouvrage : CORSICA COMMERCIAL CENTER AJACCIO
BET Fluides : BECICE MONTAUBAN (82)
Installateur : THERMATIC (12) (dep. 12)
Installed products:
High schools
73 - Savoy
Année : 2015
Maître d'ouvrage : CONSEIL RÉGIONAL
BET Fluides : BEVM
Installateur : KELETCHIAN (dep. 69)
Installed products:
High schools
40 - Landes
Année : 2015
Maître d'ouvrage : CONSEIL RÉGIONAL
BET Fluides : CETAB
Installateur : SPIE SUD OUEST (dep. 64)
Installed products:
Independent commercial catering
56 - Morbihan
Année : 2016
Maître d'ouvrage : COOPÉRATIVE BIO GOLFE
BET Fluides : GUEGUEN PERENNOU
Installateur : MISSENARD QUINT (dep. 56)
Installed products:
Community restaurants / RIE
79 - Deux-Sèvres
Année : 2016
Maître d'ouvrage : MAIF
BET Fluides : DELTA ENERGIES
Installateur : HERVE THERMIQUE (dep. 79)
Architecte : AA ARCHITECTES
Installed products:
Bars
01 - Ain
Année : 2014
Installateur : ERIT ET SERRANO (dep. 38)
Installed products:
Student residences
24 - Dordogne
Année : 2015
BET Fluides : INTECH
Installateur : SALLERON (dep. 24)
Installed products:
Offices only
44 - Loire-Atlantique
Année : 2016
Maître d'ouvrage : BOUYGUES BÂTIMENT GRAND OUEST
BET Fluides : PATRIARCHE
Installateur : CESBRON GROUPE DALKIA (dep. 44)
Architecte : GEY BAPTISTE
Installed products:
Restaurant chains
13 - Bouches-du-Rhône
Installed products:
Restaurant chains
69 - Rhône
Année : 2012
Maître d'ouvrage : GIE VAPIANO
BET Fluides : ABAC
Installateur : EGA DESBROSSES (dep. 71)
Architecte : EXCOFFON LYON
Installed products:
Hotel residences
37 - Indre-et-Loire
Installed products: