UTBS ECOWATT® - UTBS ECOWATT® PRO-REG

Old ranges

Ceiling lights - Reaction

FLAG Obsolete
UTBS View larger

UTBS ECOWATT® - UTBS ECOWATT® PRO-REG

Old ranges


Ceiling lights - Reaction

ERP-OK-Q-151008.gif PIC-isolation-renforcee PIC-batterie-chaude-froide
  • Extra flat central: height 360 to 500 mm
  • Low consumption freewheel motor-fans
  • Double skin with 25 mm mineral wool insulation
  • Flow rates from 500 to 7,400 m3 / h
  • Pre-filters removable on 4 sides
  • Indoor and outdoor version

Application

Introduction of fresh air, heating, air conditioning.
Installation inside or outside of buildings.
Floor, ceiling or vertical mounting (without vertical coil).

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

4 sizes:
  • Size 2: height 360 mm
  • Sizes 3 and 5: height 410 mm
  • Size 8: height 500 mm
Flow rates from 500 to 7,400 m3 / h.

Additional boxes
  • 2 or 3-way mixing boxes.
  • Silencer 750 and 1,100 mm.
  • Plenums.
  • Electric battery boxes.
  • Direct expansion and water coil boxes.
  • Fan boxes with pressure tap and cable gland.
  • Filter boxes with pressure taps.
UTBS
  • AHU delivered without frequency converter or regulation.

UTBS PRO-REG
  • AHU delivered with frequency converter and wired mounted control:
    • Variable flow (VAV)
    • Constant flow (CAV)
    • Constant pressure (COP)
  • Regulation by integrated CORRIGO PLC specific to VIM .
  • Communicating ModBus on RS485 port and BacNet IP on TCP / IP port.
  • ETD remote touch control.

Construction
  • Frame in extruded aluminum profiles.
  • Kit for fixing the boxes together consisting of a gasket and 4 sets of screws, nuts and washers.
  • Double skin panels in galvanized steel coated with RAL 9010 exterior
  • 25 mm mineral wool insulation, fire classification A1 according to standard 13 501.1 (non-combustible).
  • Hinged doors for easy access to the control unit.
  • Left or right easement.
  • Suction and / or blowing ID registers.
  • Roof and hood for outdoor versions.

Equipment of the main box and additional boxes (UTBS models)

Filtration
  • Pre-filter (G4, M5 or M6) with pressure tap.
  • Filter (M6, F7, F8 or F9) with pressure tap.
  • F7 to F9 HPE (High Energy Performance) filters with a holding system made up of two tightening handles: perfect sealing with the frame and easy disassembly.
  • Extraction of G4 and M5 filters on 4 sides: choice to be defined when ordering.
  • Extraction of filters M6 to F9 on 2 sides: choice to be defined when ordering.

Batteries
  • Hot water coils 2, 4 or 6 rows (galvanized frame, copper tubes and aluminum fins).
  • 4 or 6 row cold or reversible water coils (galvanized frame, copper tubes, aluminum fins, 304 stainless steel condensate tray and droplet separator).
  • Electric coils (galvanized frame and armored resistances) with manual and automatic reset protections, as well as an anti-radiation screen.

Motorized fans
  • Dynamically balanced reaction freewheels with direct coupling to the motors.
  • Foot-mounted motors B3, 1 speed three-phase 230 / 400V, 50Hz, IP54, class F, IE1 up to 0.55 kW, IE2 beyond, with integrated thermal protection with closed contact at rest (PTO).
  • Motor powers from 0.25 kW to 1.1 Kw.

Model UTBS PRO REG

Main box
  • M5 pre-filter or F7 filter as standard with pressure tap.
  • Optional pre-filter G4 or M5 before filter F7, filters F6 to F9 optional.
  • 2 or 4 row hot coils.
Regulated additional box
  • A 2-way mixing box.
Motorized fans
  • UTBS-2: 0.55kW,
  • UTBS-3: 0.75kW,
  • UTBS-5: 2 x 0.75kW,
  • UTBS-8: 2 x 1.1kW.
Regulation
  • The integrated regulation allows 3 operating modes: variable flow (VAV), constant flow (CAV), constant pressure (COP)
  • The regulation manages a 2-way mixing box according to the fresh air and return air temperatures, a slave fan.
  • The UTBS is supplied in CAV constant flow control mode. Provide the TDPD pressure probe for use in COP constant pressure regulation mode, a 0-10V probe for VAV variable flow control.
Main box

UTBS_avec_Haut-Larg

Left easement as standard (seen in the direction of the air)

UTBS 2

UTBS 3

UTBS 5

UTBS 8

A (mm)

360

410

410

500

B (mm)

750

1100

1500

1900

Unit lengths depend on configurations, see dimensions below.


Main cabinet configurations

UTBS-UTBS-PRO-REG-conf1-dim

UTBS-UTBS-PRO-REG-conf2-dim

UTBS-UTBS-PRO-REG-conf3-dimUTBS-UTBS-PRO-REG-conf4-dim

UTBS-UTBS-PRO-REG-conf5-dimUTBS-UTBS-PRO-REG-conf6-dim

UTBS-UTBS-PRO-REG-conf7-dimUTBS-UTBS-PRO-REG-conf8-dim


UTBS-UTBS-PRO-REG-conf9-dimUTBS-UTBS-PRO-REG-conf10-dim

UTBS-UTBS-PRO-REG-conf11-dimUTBS-UTBS-PRO-REG-conf12-dim


UTBS-UTBS-PRO-REG-conf13-dimUTBS-UTBS-PRO-REG-conf14-dim


BC2: Hot coil 2 rows;
BC4: 4-row Hot Coil;
BF4: Cold coil (or reversible) 4 rows;
BF6: Cold coil (or reversible) 6 rows;
X4: 4-row direct expansion coil;
X6: 4-row direct expansion coil;
BE: Electric Battery;
V: Fan;
G4: G4 filter;
F7: Filter F7;
* Configurations available with simultaneous hot and cold coils (up to 8 rows).

Main box weight

Components

UTBS 2

UTBS 3

UTBS 5

UTBS 8

Motor-fan

0.25 Kw

16

20

40 *

46 *

0.37 kW

17

21

42

48

0.55 kW

18

22

44 *

50 *

0.75 Kw

25

50 *

56 *

1.1 Kw

58 *

Filters

G4 / M5

2

4

6

8

F7 / F9

4

6

8

10

Batteries

BC2

6

9

12

12

BC4 / BF4 / X4

9

13

18

26

BC6 / BF6 / X6

11

18

24

36

BE

6

9

12

14

Casing

750 mm

35

50

60

75

969 mm

45

60

75

95

1205 mm

55

75

95

120

1455 mm

70

90

115

145

* The indicated weight includes the 2 motor-fans

Close Open Installation instructions

X