VORAX® CONFORT

Multipurpose hoods

Capture - Broadcast

VORAX® CONFORT View larger

VORAX® CONFORT

Multipurpose hoods


Capture - Broadcast

Low speed diffusion OPTAIR® Cuisine

  • Improved comfort by low speed diffusion
  • Rigid and hygienic design
  • Visible faces in AISI 304L stainless steel with SB brushed finish
  • Height 400 and 500 mm
  • Hood with vertical sides at constant height
  • Large retention volume
  • Cheeks without visible mark

Application

Capture and filtration of pollutants and heat.
Diffusion of air at low speed from the front.
Ensures staff comfort and contributes to better capture efficiency.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Single back-to-back or double central.
Central hoods formed by back-to-back assembly of 2 back-to-back hoods with partitions.
Monobloc modules length 1000, 1500, 2000, 2500 and 3000 mm.
Extended depth: 1250, 1500 or 1750 mm.
Height: 400 and 500 mm.
Dimensions and finishes identical to the models: CHEF, FOUR, LAVERIE and INDUCT from the VORAX® range.


Hood
  • Hood at constant height for a maximum compartment volume.
  • Allows the introduction of air at low speed through its front face thanks to a double perforation:
    • Flow up to 1200 m3/ h / linear m for h = 500 mm - ΔP = 60 Pa.
    • Flow up to 960 m3/ h / linear m for h = 400 mm - ΔP = 60 Pa.
  • Isolated supply chamber equipped with a flow balancing and distribution device.
  • Pressure tap.
  • Removable panel for access to the blowing damper and the supply chamber for periodic cleaning.
  • Self-supporting construction without visible fixing or sharp edges for cleaning without risk of cuts. Cheeks without visible marks such as rivets and studs.
  • Lateral reinforcements, in 15/10th galvanized steel, 50 mm high, integrated into the hood, ensuring the rigidity of the whole.
  • Leveling adjustment from inside the hood and clip-on mounting covers.
  • Gusset at the end of the sensor for a rigid junction between 2 modules while allowing a large passage of air.
  • Visible faces in AISI 304L (1.4307) austenitic stainless steel with SB brushed finish. Back and top faces in galvanized steel.
  • Standard filters galvanized media M0 stainless steel frame 397x472x25 mm.
  • Stainless steel cover plate.
  • Perimeter gutter.
  • Stainless steel purge and plug - 1/2 ”gas thread.

Packaging
  • Packaged in a crate in heat-shrinkable film.
  • Stainless steel exterior faces protected by PVC film.
VORAX® CONFORT
Optional lighting - Delivered undrilled

Underlined = dimensions of model 400 - Not underlined = model 500



Module

Total length*

Capture length

Number of holes

A

B

D

P perforation dimension

Advanced 1250

Advanced 1500

Advanced 1750

Extraction

Blowing

H400

H500

F

G

F

G

F

G

1000

1004

1000

1

1

502

968

910x285

910x385

507

655

632

655

757

655

1500

1504

1500

1

1

752

1468

1410x285

1410x385

507

1265

632

1265

757

1265

2000

2004

2000

2

2

514

976

1968

1910x285

1910x385

507

1265

632

1265

757

1265

2500

2504

2500

2

2

645.5

1213

2468

2410x285

2410x385

507

1265

632

1265

757

1265

3000

3004

3000

2

2

645.5

1713

2968

2910x285

2910x385

507

1265

632

1265

757

1265

* Total length of assembled modules: 3504, 4004, 4504, 5004, 5504, 6004

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Close Open Electrical / ATEX Certificates

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

Commercial leaflet (FCOM)

OPTAIR Kitchen
Download OPTAIR Cuisine Media locked
NEW - Software for calculating flow rates and sizing hoods in professional kitchens
OPTAIR CUISINE must be completely re-installed.

For any operating problems, please send your request by email to optair@vim.fr

  • Calculation of extraction, compensation and induction flow rates in the kitchen according to standard NF EN 16282-1.
  • Automatic sizing of hoods according to standard NF EN 16282-2.
  • Integrates different collection systems (standard hoods, welded hoods, UV welded hoods, filtering ceilings, hoods with capture only, inductive curtain, etc.)
  • Takes into account the characteristics of the cooking appliances, the efficiency of the capture system, the mode of fresh air diffusion and numerous installation parameters.
  • Presents the products and systems offered by VIM in professional kitchens with links to catalog pages, prescription texts and installation instructions.











Close Open A LA BONNE HEURE - LONS

Restaurant chains

64 - Pyrénées-Atlantiques

B'TWIN VILLAGE - LILLE

Close Open B'TWIN VILLAGE - LILLE

Shopping centers

59 - North

Close Open COLLEGE LA CHAMPAGNE - BROCHON

Colleges

21 - Côte-d'Or

Close Open CUISINE CENTRALE CENTRE PSYCHOTHERAPIQUE - BOURG EN BRESSE

Central kitchen / Food industry

01 - Ain

Close Open EHPAD (150 LITS) - QUEVERT

Residences for the elderly

22 - Côtes-d'Armor

Close Open EHPAD - MOULIN NEUF

Residences for the elderly

24 - Dordogne

HOPITAL CARDIO VASCULAIRE PULMONAIRE - LILLE

Close Open HOPITAL CARDIO VASCULAIRE PULMONAIRE - LILLE

Hospitals

59 - North

Close Open LECLERC GRAND AJACCIO BALEONE

Shopping centers

2A - Corse-Du-Sud

Close Open LYCEE FRANCOIS CEVERT - ECULLY - RESTRUCTURATION

High schools

69 - Rhône

MEDIATHEQUE L'AGORA - METZ

Close Open MEDIATHEQUE L'AGORA - METZ

Media library

57 - Moselle

RESTAURANT PERRUCHE - PRINTEMPS HAUSSMANN

Close Open RESTAURANT PERRUCHE - PRINTEMPS HAUSSMANN

Independent commercial catering

75 - Paris

X