KAMOUFLAGE 1VP / ATOUT 1V P

Gate shutters

Flush ceiling - BA10 or painted RAL 9010 finish

KAMOUFLAGE 1V P View larger

KAMOUFLAGE 1VP / ATOUT 1V P

Gate shutters


Flush ceiling - BA10 or painted RAL 9010 finish

ce.jpg nf.jpg

  • Easy installation
  • Reinforced sealing
  • Reinforced thermal insulation
  • Low pressure drop
  • Aesthetic integration
  • Standard or ASSET version


Application

Intended for mechanical or natural smoke extraction from premises.
Remote controlled Safety Actuated Devices (DAS) intended for smoke extraction.
Opening on command of the CMSI (Fire Safety Control Center).
Use inside buildings.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Aesthetic smoke evacuation damper with a remote control gate for ceiling mounting without a cover grille.
KAMOUFLAGE 1V P: model with central plate flush with the frame, possibility of painting the shutter.
  • 1 leaf: 1V60 EI60S and 1V120 EI120S, dimensions (LxH): 350x385 to 700x775 mm.
KAMOUFLAGE ATOUT 1V P: model with metal central plate, white lacquered finish RAL 9010.
  • 1 leaf: 1V60 EI60S and 1V120 EI120S, dimensions (LxH): 350x385 to 700x715 mm.


Description
  • Anodized aluminum frame.
  • 1 leaf in refractory material pivoting on a hinge.
  • 1 or 2 gas jacks (depending on the size) for opening the leaf.
  • KAMOUFLAGE 1V P: shutter to be painted or upholstered for perfect integration into the ceiling of the room.
    • Option: primer bonding layer on the shutter frame.
  • KAMOUFLAGE ATOUT 1V P: leaf in refractory material pivoting on hinges, covered with a metal panel supplied with a protective film in white RAL 9010 finish.
  • Always provide a KAP pre-frame for ceiling mounting.
  • The components codified in the TARIFF pages are without option. The order must imperatively be accompanied by at least:
    • A 24 or 48V trip coil with VD shunt or VM break: optionally VD24 or VM24 or VD48 or VM48.
    • Unipolar or bipolar end and start of stroke position contact: FDCU or FDCB option.


1 - refractory material
2 - KAP pre-framework
3 - Sealing (ex. Plaster)
a) Nominal dimensions of the shutter
b) Booking odds
c) External dimensions of the shutter
Weight (kg): Refer to the technical notices on vim.fr

Close Open Detailed specifications

Close Open Public tariff price

Price catalog pages (CP)

Close Open Fire / Smoke extraction certificates

Close Open Performance / Environment Certificates

Declaration of performance (DOP)

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

Commercial leaflet (FCOM)

X