  • Aesthetic finish GZ60
  • 60 to 120 minutes fire resistance
  • Easy to install


Application

Intended for natural ventilation of rooms - can only be installed through a wall.
Restoration of the fire rating of a wall, slab or door through which the air temperature exceeds 100 ° C.
Use inside buildings only.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

GZ60:
  • Dimensions (Ln x Hn): 100 x100 to 800 x 400 mm.
  • Anti-vision chevron-shaped fins.
  • RAL 9022 aluminum finish as standard. Optional: RAL 7024 or RAL 9016.
GE60 - GE90 - GE120:
  • Dimensions GE60 - GE90 (Ln x Hn): 100 x100 to 800 x 400 mm.
  • GE120 dimensions (Ln x Hn): 150 x 100 to 800 x 400 mm.
  • Vision grid.
  • Anodized aluminum finish.
GE60 XL - GE120 XL:
  • Dimensions (Ln x Hn): up to 1200 x 800 mm.
  • Vision grid.
  • Anodized aluminum finish.

Description
  • Dimensions width x height from 100x100 to 800x400 in steps of 50mm as standard and in steps of 100mm beyond up to 1200x800.
  • Rectangular fire grill made of plastic slats filled with intumescent fire bands.
  • The intumescent bands react and expand when the temperature exceeds 100 ° C to quickly close the opening, thus preventing the spread of flames.
  • Installation in an environment where the relative humidity does not exceed 70%.
  • Clean with a soft, dry cloth. Do not use an abrasive sponge, detergent (alkaline / acid), or volatile solvents such as alcohol and other solvent-based products. The use of this type of product can damage the grill.
  • Installation of the grille with the horizontal slats.
  • Maximum temperature of use 60 ° C.
  • Operating pressure -5 to +10 Pa.
  • Use of BCM mastic glue to finish installing the grille in the traversed wall (GZ60, GE60, GE90).
GZ60


Reservations
Model Mounting type Material Dimensions
GZ60
Massive wall Aerated concrete LxH
Massive slab Aerated concrete (L + 30) x (H + 30)
Flexible wall plasterboard (L + 30) x (H + 30)
Door panel wood LxH


GE60/ 90
Ge60-90-dim.png

GE60-XL
Ge60-XL-dim.png

GE120 / GE120-XL




Reservations
Model Mounting type Material Dimensions
GE60 / GE90 Massive wall Aerated concrete LxH
GE60 XL Massive wall Aerated concrete mini: LxH
maxi: (L + 50) x (H + 50)
GE120
GE120 XL
Massive wall Aerated concrete (L + 15) x (H + 15) (Ytocol sealing)
(L + 35) x (H + 35) (plaster sealing)