KDTA BP F400 - KDTR BP F400

F400 120 extraction boxes

Transmission - Action or Reaction < 2,000 m3/h

KDTA BP F400 - KDTR BP F400 View larger

KDTA BP F400 - KDTR BP F400

F400 120 extraction boxes


Transmission - Action or Reaction < 2,000 m3/h

Erp.jpg Not ErP compliant
For smoke extraction alone or process ventilation
f400.jpg CE.jpg coffret-monte.jpg isolation-acoustique logiciel.jpg

  • Suitable for smoke extraction in waiting rooms for the disabled
  • F400 120 approved (400 ° C 120 min)
  • Fan with action and reaction
  • Variable pulley as standard
  • Compact for installation in tight spaces
  • Circular in-line connection
  • Mounted electrical accessories

Application

Extraction of fumes and hot gases in case of fire.
Particularly suitable for smoke extraction in waiting rooms for disabled people in accordance with article AS4 of the decree of June 25, 1980.
Maximum continuous air flow temperature 80 ° C.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

2 types of wheel: action or reaction.
1 size 200, 2 motor powers per size.
KDTA 200 BP action turbine: Use in comfort and smoke extraction, flow from 100 to 2000 m3/h, pressure from 100 to 500 Pa.
KDTR 200 BP reaction turbine: Use in comfort and smoke extraction, flow from 100 to 1900 m3/h, pressure from 50 to 500 Pa.
Horizontal version in line or with vertical discharge.

Construction
  • One-piece box made of galvanized sheet steel.
  • Removable side panels on both sides for easy access.
  • Connection taps with Véloduct® seals.
  • KDTA double inlet action turbine, galvanized steel, dynamically balanced.
  • KDTR double inlet turbine with reaction in painted galvanized steel dynamically balanced.
  • Standard variable pulley offering a wide range of use and allowing easy adjustment on site.
  • In-line suction and discharge (horizontal version) or top discharge (vertical version).
  • Engine out of airflow.
  • Standard engine access on the left, air direction, on the right on request.

Motorization
  • Foot motor B3, IP55, class F:
    • 1 speed single phase 230V, 50Hz, 2 or 4 poles IE1.
    • 1 three-phase speed 230/400V, 50Hz 2 or 4 poles IE2 or IE3.
    • 2 three-phase speeds 400V, 50Hz, 2/4 Dalhander poles.
    • Thermal protection by PTO as an option.
    • 60Hz single-phase or three-phase power supply: CE F400 marking retained, contact us.

Selection of smoke extraction fans
Configuration in horizontal rejection

KDTA-R-BP-H-dim

KDTA F400 BP - KDTR F400 BP

AH

AV

B

C

CV

D

E

F

J

M

N

P

motor max.

756

756

555

488

568

575

737

400

48

267

605

518

71



Vertical discharge configuration

KDTA-R-BP-V-dim

KDTA F400 BP - KDTR F400 BP

AH

AV

B

C

CV

D

E

F

J

M

N

P

motor max.

756

756

555

488

568

575

737

400

48

267

605

518

71

Close Open Detailed specifications

Close Open Public tariff price

Close Open Installation instructions

Installation instructions (NT)

Close Open Fire / Smoke extraction certificates

Close Open Performance / Environment Certificates

Declaration of performance (DOP)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Commercial documents

Commercial leaflet (FCOM)

OPTAIR Ventilation
Download OPTAIR Ventilation Media locked
VMC SMOKE EXHAUST
OPTAIR-Ventilation.png Selection of turrets and boxes: KDT / KSH / TCD / KUBAIR / TED
  • VScreation of a technical sheet per fan including the requested operating point on the curve, the technical and acoustic characteristics, and the overall dimensions
  • Printing possibility
  • Link to all technical pages Catalog
KCTR F400
KDTA BP
KDTA F400
KDTR BP
KDTR F400
KSHA
KSHP
KSHR
KUBAIR F400 CC
KUBAIR F400 ECOWATT CC
KUBAIR F400 ECOWATT MV
KUBAIR F400 MV
TCDH F400
TCDV F400
TEDH F400
TEDH F400 ECOWATT
TEDV F400
TEDV F400 ECOWATT
OPTAIR VVTP
Download OPTAIR VVTP Media locked
For any operating problems, please send your request by email to optair@vim.fr
VMC SMOKE EXHAUST
OPTAIR-VVTP.png

Flow calculation Ventilation of a Protected Technical Volume

  • Calculation based on the smoke extraction flow rate, the installed extractor, the duct network and the characteristics of the room.
  • Facilitates the optimization of flow rates by adjusting the different parameters
  • Selection of air intake grilles or shutters.
  • Summary technical sheets.
Fans

Grids

Close Open COLLEGE GASTON RAMON - DEMI PENSION

Colleges

70 - Haute-Saône

HOTEL ROYAL HAINAUT - VALENCIENNES

Close Open HOTEL ROYAL HAINAUT - VALENCIENNES

Hotels

59 - North

Close Open VA PIANO CONFLUENCE - LYON

Restaurant chains

69 - Rhône

X