MOT

Engines and transmissions

Asynchronous motors B3

MOT View larger

MOT

Engines and transmissions


Asynchronous motors B3

  • Complete mono and sorting range
  • Reliable engines approved on our products
  • Compatible with frequency inverters
  • High efficiency IE2 and very high efficiency IE3 motors available


Application

For our fans using B3 foot motors: KDTA / KDTR / KCTR / HUDT / HUCF / KSHP / KSHA / KSHR / KSTA / KSTV.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Single phase 0.12 kW to 3 kW.
  • 1 speed 2 and 4 poles.
Three-phase 0.12 kW to 55 kW.
  • 1 speed 2, 4 and 6 poles. IE2 and IE3 (and IE1 from 0.12 to 0.55 kW).
  • 1 speed 8 poles. IE1, IE2 and IE3.
  • 2 independent winding speeds 4/6 and 6/8 poles.
  • 2 speeds Dalhander windings 2/4, 4/8 and 6/12 poles.

Description

Single-phase AC motors with permanent capacitor:
  • 1 single phase speed, 230 V, 50Hz.
  • Aluminum frame.
  • Cage rotor, ball bearings.
  • Form B3T, IP55, class F, temperature rise 80 ° C, service S1, ambient 40 ° C.
  • Compatible with voltage variator (oversize the motor power by one size compared to use without voltage variation).
Three-phase AC motors:
  • 1 three-phase speed 230/400 V up to 7.5kW or 400/690 V from 9.2 kW, 50Hz.
  • 2 three-phase speeds 400 V, 50Hz.
  • Aluminum or cast iron casings (see characteristics).
  • Cage rotor, ball bearings.
  • 2 directions of rotation.
  • Form B3T, IP55, class F, temperature rise 80 ° C, service S1, ambient 40 ° C.
  • Compatible with frequency converter, range 15 to 50Hz (variable speed drive from 30 to 100 %).
Option - Supply and assembly of a PTO probe.
  • Thermal Protection with Opening incorporated in the motor winding.
  • When the motor winding exceeds the temperature limit permitted by its temperature rise class, the thermal protection contact opens, allowing the fault to be signaled. The thermal protection must be connected to the motor control circuit.
  • Characteristics :
    • Normally closed contact, normally closed.
    • Trigger temperature: 145 ° C.
    • Breaking capacity: 2.5A at 400V.
Note: in SMOKE EXHAUST use, DO NOT CONNECT the thermal protection.
Single phase motor




Height
axis

A

AA

B

C

D

E

F

GA

H

HA

K

PE

L

TBH

TBW

TBS

AD

AC

63

100

120

80

40

11

23

4

12.5

63

8.3

7x10

M16x1.5

215

92.5

116.5

20

180

130

71

112

132

90

45

14

30

5

16

71

9.5

7x10

M20x1.5

240

92.5

115.5

20.5

194

145

80

125

157

100

50

19

40

6

21.5

80

10.6

10x13

M20x1.5

290

110

140

32

227

165

90S

140

172

100

56

24

50

8

27

90

11.5

10x13

M20x1.5

330

110

140

32

245

185

90L

140

172

125

56

24

50

8

27

90

11.5

10x13

M20x1.5

360

175

148

25

245

185

100

160

196

140

63

28

60

8

31

100

13.3

12x16

M20x1.5

385

175

148

20

265

205





Three-phase motor

MOT-tri-dim


Axle height

Carcass

A

AA

AB

AC

AD

B

BA

BB

C

D

63

Alu

100

19

116

125

119

80

23

95

40

11d6

71

Alu

112

28

134

140

127

90

24.5

108

45

14d6

80

Alu

125

32

155

159

136

100

28

124

50

19d6

90S / L

Alu

140

35

170

179

155

100/125

24

146

56

24d6

100L

Alu

160

40

196

200

160

140

30

170

63

28d6

112M

Alu

190

46

220

223

184

140

32

170

70

28d6

132S / M

Alu

216

44

248

270

212

140/178

37

170/210

89

38k6

132M

Melting

216

51

248

271

218

178

55

225

89

38k6

160M / L

Melting

254

64

308

329

264

210/254

63

254/298

108

42k6

180M / L

Melting

279

78

350

360

279

241/279

70

294/332

121

48k6

200M / L

Melting

318

82

385

402

317

267/305

82

332/370

133

55m6

225S / M

Melting

356

80

436

455

384

286/311

124

412

149

55m6 * / 60m6

250S / M

Melting

406

100

506

486

402

311/349

146

467

168

60m6 * / 65m6

280S / M

Melting

457

100

557

599

472

368/419

151

517

190

75m6

* 2 pole motors only


Axle height

E

ES

F

G

GD

H

HA

HC

HD

K

L

S1

d1

63

23

14

4

8.5

4

63

6

125

182

7

216

2xM20x1.5

EM4

71

30

18

5

11

5

71

6

139

198

7

248

2xM20x1.5

DM5

80

40

28

6

15.5

6

80

8

157

216

10

276

2xM20x1.5

DM6

90S / L

50

36

8

20

7

90

9

177

245

10

329

2xM25x1.5

DM8

100L

60

45

8

24

7

100

12

198

265

12

376

2xM25x1.5

DM10

112M

60

45

8

24

7

112

12

235

296

12

393

2xM32x1.5

DM10

132S / M

80

63

10

33

8

132

12

274

344

12

490

2xM32x1.5

DM12

132M

80

63

10

33

8

132

20

266

350

12

490

2xM32x1.5

DM12

160M / L

110

80

12

37

8

160

22

327

424

14.5

598/642

2xM40x1.5

DM16

180M / L

110

80

14

42.5

9

180

28

363

459

14.5

664/702

2xM40x1.5

DM16

200M / L

110

80

16

49

10

200

30

405

517

18.5

767

2xM50x1.5

DM20

225S / M

110 * / 140

100 * / 125

16 * / 18

49 * / 53

10 * / 11

225

34

453

619

18.5

856 * / 886

2xM50x1.5

DM20

250S / M

140

125

18

53 * / 58

11

250

43

493

652

24

965

2xM63x1.5

DM20

280S / M

140

125

20

67.5

12

280

42

580

752

24

1071

2xM63x1.5

DM20

* 2 pole motors only

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

X