BATE

Electric coils

Circulars - Unregulated

BATE View larger

BATE

Electric coils


Circulars - Unregulated

secu-elec.jpg Electrical safety

  • Integrated thermal protections
  • Regulation as an accessory
  • Power from 900 to 18,000 W
  • Connection by watertight class C joints

Application

Can be integrated into a horizontal or vertical network of circular ducts.
Terminal heating.
Defrost.
Maximum outlet temperature 50 ° C.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

Diameters from 125 to 500 mm.
Power from 900 to 18,000 W
Single 230 V 50Hz or three 400 V 50 Hz power supply.


Operation
  • Regulation of the supply air temperature in the duct (see principles on PULSER / TTC pages).
  • Room or return temperature regulation with or without supply air limit (see principles on PULSER / TTC pages).
  • Minimum speed = 1.5 m / s - Maximum speed 10 m / s.
  • Need to control the heating to the operation of the fan.
  • Provide a pressure switch to cut off the power supply in the event of a ventilation fault or insufficient flow (V min = 1.5 m / s).
  • Provide an MCR1 type time delay which delays the stopping of the fan to cool the pins.
  • For single-phase versions ≥ 4kW and three-phase versions, provide a contactor to cut off the power supply in the event of triggering of one of the safety thermostats. The contactor will be equipped with an auxiliary contact (NO/NC) to transfer the information to the regulation of the ventilation unit or to the BMS.
Construction
  • Circular ferrule and IP44 connection box in Aluzinc treated steel.
  • Connection by watertight class C joints
  • IP 44 grommet to cut.
  • Heating elements shielded in stainless steel 304.
  • Safety thermostats with NC contact pre-wired in series, to be connected to an external power contactor:
    1 safety thermostat with automatic reset 50°C.
    1 safety thermostat with manual reset, set point 100°C.
Accessories
  • Pressure switch, duct or room sensor or external potentiometer, time delay, regulation.
BATE-R010-dim

Ø (mm)

Power (W)

A

B

C

D

125

900 to 9000

276

373

195

48.5

160

900 to 9000

276

373

230

48.5

200

900 to 9000

276

373

270

48.5

250

900 to 9000

276

373

320

48.5

250

12000

400

497

320

48.5

315

900 to 9000

276

376

385

50

315

12000

400

500

385

50

400

900 to 9000

276

376

470

50

400

12000

400

500

470

50

500

18000

530

630

570

50

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Installation instructions

Installation instructions (NT)

Installation instructions (NT) Other

Close Open Electrical / ATEX Certificates

Electrical CE Declarations (DCCE)

Close Open Prescription assistance

Specification text (TP)

Close Open CAUDALIE

Shipping or storage

45 - Loiret

Close Open LEON DE BRUXELLES - SAINT MARCEL LES VALENCE

Restaurant chains

26 - Drome

Close Open MAROQUINERIE DU PUY - CHASPUZAC

Manufacturing premises

43 - Haute-Loire