CR120 1S

Circular check valves

Surface mounted - Low pressure drop - Ø315 maxi

CR120 1S UNIQ View larger

CR120 1S

Circular check valves


Surface mounted - Low pressure drop - Ø315 maxi

ce.jpg nf.jpg

  • Tightness class C according to standard EN 1751
  • Scalable valve
  • UNIQ FDCB universal mechanism
  • Low pressure drop
  • Time saving during assembly
  • Multi-support, without sealing

Application

Intended for the compartmentalisation of public buildings (public buildings) and high-rise buildings (high-rise buildings).
Autocontrolled or remotely controlled Actuated Safety Devices (DAS), intended to restore the fire resistance characteristics of walls or floors crossed by a duct in the event of a fire and to isolate the disaster area.
Use inside buildings.
Wall mounting possible with horizontal blade only.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

6 Sizes: Ø100 / Ø125 / Ø160 / Ø200 / Ø250 / Ø315 mm.
Surface mounting, without sealing.
4 control mechanisms:
  • MFUS: simple self-controlled mechanism.
  • BOBI VD FDCB or BOBI VM FDCB: scalable remote-controlled mechanism.
  • BOBI VD FDCB ME or BOBI VM FDCB ME: motorized remote-controlled mechanism.
  • UNIQ META VD/VM FDCB ME: motorized remote-controlled mechanism.

Description
  • Very low pressure loss (thin 20 mm moving blade with sealing gasket).
  • ATC 3 (C) waterproofing class according to EN 1751 as standard across the entire range.
  • Control mechanism completely outside the wall.
  • Galvanized steel tunnel.
  • Intumescent seal.
  • Dry installation of the valve without clogging (only screwed to the wall).
  • Extended tunnel version length 500 mm: contact us
MFUS: simple self-controlled mechanism
  • Automatic closing of the valve as soon as the temperature in the duct exceeds 72°C (72° thermal fuse).
  • Manual valve reset
  • Integrated start and end of travel contact (MFUS FDCU).

BOBI: self-controlled + remote-controlled + scalable mechanism
  • Automatic closing of the valve as soon as the temperature in the duct exceeds 72°C (72° thermal fuse).
  • Closing using a current-release coil (BOBI VM 24/48 FDCB) or current-break coil (BOBI VD 24/48 FDCB) at 24 or 48V.
  • Equipped as standard with bipolar end and start of travel contacts.
  • Manual resetting of the valve.
  • Remote reset possible on site with the addition of the ME BOBI Kit.

BOBI ME: self-controlled + remote-controlled + motorized mechanism
  • Same as remote controlled Bobi.
  • Remote reset via the integrated motor (BOBI VD FDCB ME or BOBI VM FDCB ME).

UNIQ META: self-controlled + remote-controlled + motorized mechanism
  • Automatic closing of the valve as soon as the temperature in the duct exceeds 72°C (72° thermal fuse).
  • Closing using a current-release coil (VD) or current-break coil (VM) at 24 or 48V voltage.
  • Supplied as standard in VM. Switch to VD by removing a switch.
  • Equipped as standard with bipolar end and start of travel contacts.
  • For testing, “manual” rearmament via a motor powered by a 9V battery included (20 rearmaments / 2 years).
  • Remote reset via the integrated motor.

Selection of flaps and shutters


Mechanisms

MFUS

BOBI

UNIQ

P

72

92

92

Q

123

136

136

Z

70

83

83



ØDn (mm) Ø100 Ø125 Ø160 Ø200 Ø250 Ø315
HAS 279 299 339 374 419 474
Ød 160 180 220 255 300 355
Reservation: Ød+20 180 200 240 275 320 375

Weight (kg)

Ø100

Ø125

Ø160

Ø200

Ø250

Ø315

MFUS

1.60

1.80

2.10

2.60

3.30

4.20

BOBI

2.95

3.15

3.45 3.95 4.65 5.55

UNIQ META

2.95

3.15

3.45

3.95

4.65

5.55

Close Open Detailed specifications

Text catalog pages (CT)

Close Open Public tariff price

Price catalog pages (CP)

Close Open Fire / Smoke extraction certificates

Close Open Performance / Environment Certificates

Declaration of performance (DOP)

Close Open Prescription assistance

Specification text (TP)

Close Open Commercial documents

X