PULSER - TTC

Battery regulation

Electric coil regulators

PULSER - TTC View larger

PULSER - TTC

Battery regulation


Electric coil regulators

temperature.jpg Temperature regulation

  • Adapts power as needed
  • Without magnetic disturbance
  • Ease of use

Application

Modulation of the heating power according to the desired temperature setpoint in a room or in the duct.
The operation of the electric heaters must be slaved to the operation of the fan and associated with several safety devices (depressostats, post-ventilation delay, overheating thermostats, etc.).
Electronic regulators equipped with triacs.

  • Description

  • Dimensions

  • Documentation

  • Public Price

  • Software

  • References

PULSER: regulation of single-phase batteries
  • 3 16A regulators (3.6kW max).
  • Ambient mounting. Internal set point sensor and adjustment.
    • M: ambient mounting with input for min / max duct limitation probe.
    • ADD: 16A (3.6kW) single-phase additional unit to double the operating power. Ambient mounting.
TTC: regulation of three-phase batteries
  • 3 regulators 25A, 40A, 80A TTC25 / 40F / 80F.
  • TTS6D: sequencer for multi-stage control (6 relay outputs).
  • Standard: DIN rail mounting.

Description

PULSE
  • Progressive control: chrono-proportional control by triac.
  • Can be used with an integrated or external probe (NTC probe: TGK or TGR).
  • Adjustment of internal or external set point (TBI potentiometer).
  • Supply voltage: single phase 230VAC.
  • Set point: 0… 30 ° C (the probe determines the temperature range).
  • Power output:
    • 16A (mini 1A),
    • 3.6kW max.
  • Protection index: IP30.
  • P or PI regulation, automatic adaptation.
Tax incl.
  • Progressive control, chrono-proportional regulation by triac.
  • Automatic adaptation of the P or PI function.
  • Works with an external 0… 10V control signal.
  • Supply voltage: 3 phases 210… 415VAC.
  • Power output:
    • 25A, 17kW, tri 400V (TTC25),
    • 40A, 27kW, tri 400V (TTC40F),
    • 80A, 55kW, tri 400V (TTC80F).
  • 0… 30 ° C set point: the probe determines the range (NTC probe: TGK or TGR).
  • Inputs 2 probes: main probe and min / max limit probe.
  • 0… 10V control signal.
  • Protection index: IP20.
TTS
  • In addition to the TTC to increase control capacity.
  • Controlled by TTC25 / 40F / 80F regulators or any regulator with 0… 10V output.
  • Supply voltage: 24 VAC (with TRAFO transformer).
  • Output up to 6 relays, 2A, 240VAC, NO relay. For sequential or binary control of a power contactor.
  • Input, 0… 10V for TTC control.
  • Protection index: IP20.
  • Possibility of controlling 1 to 5 battery power stages (provide additional power contactors) and a 3 min post-ventilation thanks to the relay output.
PULSER M - PULSER ADD
PULSER-M-ADD-dim
Tax incl. 25
TTC-25-dim

TTC 40F

TTC-40F-dim


TTS 6D

TTC-6D-dim

X